1) Program Set Point – Enter the set point

number from 1 to 32. This determines

the set point that subsequent menus will

operate on. Go to “PROGRAM SET

POINT” menu (next page).

2) Set Points Enabled/Disabled – This

is the master switch for all set points.

When disabled no Set Point will oper-

ate. You must Enable the set points here

for any set point to operate.

3) View Status – The LCD displays all 32

Set Points along with a status indication.

The 9850 queries the master CellScale

for status. This can take several seconds

to fully update (a low priority task for

the CellScale). Select the desired Set

Point to program with either the cursor

keys, or key in the number.

Pressing a number from 1-3 will cause groups to highlight
waiting for a second key. If no second key is pressed
within 3 seconds, Set Point 1, 2, or 3 is selected. To go
immediately to Set Points 1-3, press the ENTER key after
pressing 1-3. Press the ALPHA key to see the Set Point
names (if any) entered in the 9000.

Once the desired Set Point is high-

lighted, press the

ENTER

key to

set up the set point response. Go to

“PROGRAM SET POINT” menu (next

page).

4) View Status w/Name – Same as above

except the Set Point name is displayed

along with the Status. Press the

ALPHA

key to enter or edit a set point name. Use

the Cursor keys to see the second half

of set points (17-32).

5) Clear Latches – Any set point that is

latched on is cleared with this selection.

However, if the tripped condition still

exists, the set point will remain on and

latched.

SET POINT SETUP MENU

There are four ways to program values, operators, and remote relays for Set Points. 1) Use the Terminal Interface

Mode at the CellScale, 2) use a 3750CS, 3) use a 9750A, or 4) use the 9850.
To Enter the Set Point Setup Menus

1) Press

SETUP

.

2) Select “Set Points” by pressing

[2]

.

3) The “MASTER SET POINTS” menu appears. Menu items 1-5 are discussed next.

1 S 9 S 17 S 25 S

2 S 10 S 18 S 26 S

3 S 11 S 19 S 27 S

4 S 12 S 20 S 28 S

5 S 13 S 21 S 29 S

6 S 14 S 22 S 30 S

7 S 15 S 23 S 31 S

8 S 16 S 24 S 32 S

SP1-NameS SP9 Name-S

SP2-NameS SP10Name-S

SP3-NameS SP11Name-S

SP4-NameS SP12Name-S

SP5-NameS SP13Name-S

SP6-NameS SP14Name-S

SP7-NameS SP15Name-S

SP8-NameS SP16Name-S

2 Set Points DISABLED

2 Set Points ENABLED

5 Clear Latches

Cleared

Len 0 F4 Menu

Max 8 ENT Save

Pos 1

SETPOINT XX NAME

1

ENTER

To Program Set

Point Menu

To Edit Highlighted

Set Point Name

0-9

or

Cursors

0-9

or

Cursors

MASTER SET POINTS

1 Program Set Point

2 Set Points

ENABLED

3 View Status

4 View Status w/Name

5 Clear Latches

6 Mom Timeout Ш.Ш s

See General Text Editing

Procedure

MASTER SET POINTS

ESC

!

SETUP

2

DEF

2

DEF

3

GHI

4

JKL

5

MNO

ALPHA

A

a

1

ALPHA

A

a

1

ALPHA

A

a

1

1

ABC

PROGRAM SET POINT

ESC exits no change

ENTER edits value

Ø-9 replaces value

1

min = 1 max = 32

^ incs, v decs value

Status Indicators

U Unknown – the CellScale has not yet

reported the Set Point Status

O Off – All Set Points are off
D Disabled – This Set Point is off
I Inactive – Set Point not tripped (inactive

state).

A Active – Set Point active and tripped
T Test – Test or Manual Mode forced on
L Latched – Set Point tripped and latched