Set points, Driving output modules – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 17

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 17

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

1
2
3
4
5

1
2
3
4
5

1
2
3
4
5

1
2
3
4
5

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

FIELD WIRING

TERMINAL STRIP

FUSE 5A

MODULE

POSITION

1

2

3

4

+VCC

GND

GND

GND

GND

LOGIC

LOGIC

LOGIC

LOGIC

TERMINAL STRIP

FOR LOGIC

9850 P3

Set Points Port

Pin 1- 5V Out

Pin 2 - SP2

Pin 3 - SP3

Pin 4 - SP5

or GND

Pin 5 - SP1

Set Points

BRN

WHT

BLUE

BLK

GREY

Driving Output Modules

Pin 5 - SP4

PINK

Use of SP5 requires

Jumper JP6

positioned 1-2.

Insulate all unused wires.

TO POSITION 5

IN LARGER RACK

GND Connections not

required for Output

modules

I/O RACK

GRAYHILL

70RCK4 or

70GRCK4 or

Equivalent

Interfacing Industry Standard I/O Modules
Standard Opto-isolated Output modules are easily driven by the 9850 Output port. MSI provides a 4 port I/O rack

prewired with the Set Points Output Cordset (MSI P/N 10082 + 13186). Hooking up the GND wire (Black) is

optional when driving output modules. Any 5V input compatible Output Module can be used. For reference, the

following Output Modules have been tested with the 9850 and fit Grayhill’s I/O Rack 70RCK4:
Grayhill AC Output Modules
70M-OAC5, 120VAC@3A, Normally-Open Zero Voltage Turn-on
70M-OAC5A, 240VAC@3A, Zero Voltage Turn-on
70M-OAC5A-11, 240VAC@3A, Random Turn-on
Grayhill DC Output Modules
70M-ODC5, 60VDC@3A, Normally-Open
70M-ODC5A, 200VDC@1A, Normally-Open
70M-ODC5B, 60VDC@3A, NO Low off leakage
This list represents only a small number of compatible Output Modules.