SECTION 7 – TOTAL / STATISTICS

TOTAL

• The 9850 can add independent weighments together and keep a counter of how many weighments were added

(Totaled). The Weighments counter can be thought of as a box or palette counter.

• “TOTAL” always uses the displayed weight, so gross and net readings can be added into the same total.

• There are two modes of Totaling which are set in the SETUP TOTAL section. The Manual mode uses the

TOTAL

key to add the current weight to the previously totaled value. The Auto mode will automatically add

the last, settled value to the total (or optionally the highest value). See “SETUP TOTAL” for instructions to

enable the AUTO TOTAL modes.

• Both modes have a means to prevent the same load from totaling twice. Once totaled, the load must be

removed from the scale before a new load can be added to the Total. Applied weight must be greater than

the Total Threshold before it can be totaled. See “SETUP TOTAL” for instructions on how to set the Total

Threshold.

To Total with the

TOTAL

Key

(Unit must be setup to Manual Total mode)

Rules for use:

1) The motion annunciator must be off, the scale must be stable unless motion is disabled in the Setup Total

menu.

2) Only readings above the High Threshold can be accumulated.

3) The scale adds the current reading (relative to the Net zero or Gross zero depending on mode) to the contents

of the accumulate register.

4) After a weighment is totaled, the weight must go below the Total Threshold before another weight can be

added to the total. This assures that a weight on the scale is only added to the total once.

AUTO TOTAL

SETUP Option, see “SETUP TOTAL” to enable Auto Total.

When the weight exceeds the Total Threshold the total function operates automatically.
There are 5 modes of Auto Total. Each mode is used in slightly different ways.
Mode 1, Autonorm: The displayed weight is held in a holding register and added when the weight returns below

the Total Threshold. The last settled reading is what will be used for totaling when the scale returns below the

Total Threshold. The user must make sure that while removing the load the scale does not stabilize enough for

a new reading or an erroneous weighment addition could occur. The last settled weight is actually added to the

total when the scale returns to below the Total Threshold.
Mode 2, Autopeak: The “AUTOPEAK” total mode works the same as Autonorm, except that the highest settled

reading will be used for totaling on return to zero, rather than the last settled reading.
Mode 3, Autoload: totals the applied weight as soon as the weight is stable (Motion Indicator off). Additional

weight cannot be totaled until the weight drops below the Total Threshold
Mode 4, Loaddrop: After pressing the

TOTAL

key, the CellScale starts a long term, motion compensated (if the

motion compensation option is installed in the CellScale), average of the current weight that ends when the weight

is dropped. This method is designed for commodity weighing of scrap metal, or other types of materials that are

loaded into rail cars, trucks, hoppers, etc., usually with a crane.

Place the weight to be totaled on the scale. When the weight has stabilized, press the

TOTAL

Key

[F1]

.

The current weight is added to the total register. If the display is setup to display the total, the display gives

an indication of how many weighments have been totaled. i.e. 6 #. There may be a small delay before the

CellScale reports back to the 9850 the new Total and Total weighments.

On Autonorm, Autopeak, and Loaddrop modes, the Total is not recorded until the weight is removed
(weight drops below the total threshold). When combining print modes with totals, this can cause the
total to lag by one reading. Use the Autoload or Onaccept modes if an immediate current weight and
totaled weight printout is required.

Mode 5, Onaccept: In conjunction with target weights set up in the set points menus, the Onaccept total mode

will automatically total settled readings that fall within the preselected accept weight window. See Section 8 “Set

Points” for information on setting accept limits.

!