Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 79

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 79

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

Press the

CLR

key rapidly 3 times and the entire string will be erased.

Press the ESC key to restore the string as it was.

Press

ENTER

to store the empty string.

Output Spaces

@B

# where “#” is the number

of spaces from 1-255

@B100

100 spaces inserted in

the string

Output ID Code

@C

1=ID and code #

2=Code # only

@C1

ID CODE **1

*14 Outputs the current ID number only.

@C1

Output Date

@D

1=ddmmmyy

2=mm/dd/yy

3=dd/mm/yy

4=Day of Wk

5=ddmmmyyyy

6=mm/dd/yyyy

7=dd/mm/yyyy

8=yyyymmdd (ISO)

@D1

@D2

@D3

@D4

@D5

@D6

@D7

@D8

30SEP02*

09/30/06

30/09/06

SATURDAY**

30SEP2006*

09/30/2006

30/09/2006

20060930

Output End-of-line String

@E

None

@E

Outputs End-of-line string. Up to 64 bytes.

Output Horizontal Tabs

@H

# where “#” is the number

of tabs from 1-255

@H10;

Outputs 10 horizontal tabs. Terminate with

semicolon for less than 3 digits.

Output Start-of-line String

@F

None

@F

Outputs Start-of-line string. Up to 64 bytes.

Select Active Channel

@nn

where “nn” is the channel

list location 01-32

@05

@26

Selects Channel List

location 5.

Selects location 26

All commands that are

channel specific are

directed to this Channel

Description

Cmd

Command Suffix

Input

examples

Output examples & comments

*= a space or place holder

Output an “@” sign

@@

@@

@ The CellScale uses the @ sign for specific

embedded commands, this command allows the

outputing of @.

None

Reset the host parser

;

None

;

This command can be used at any time to reset

the command parser

Change to previous channel

w/ Labels

@-

None

@-

Switches to previous channel and outputs SC

number, LC# and LC Name

Change to next channel

w/ Labels

@+

None

@+

Switches to next channel and outputs SC

number, LC# and LC Name

Query for current scan list posi-

tion

@?

1=Current Scan Index

2=Current Display Index

@?

Outputs SC number, LC# and LC Name

SC 1, CH 1-1, Name of Scale****

Name of scale up to 20 characters

Change to next channel

(no Label)

@#

None

@#

Switches to next channel in scan list.

Change to previous channel

(no Label)

@!

None

@!

Switches to previous channel in scan list.

Output Annunciators

@A

1=Battery Level

2=Center of Zero

3=Motion Status

4=OK to Total Status

5=Net./Gross Status

6=Channel Status

7=9850 Battery Voltage

8=Batt normal or low

9=Int temperature

@A1

@A2

@A3

@A4

@A5

@A6

@A7

@A8

@A9

BAT1 =Bat >1% BAT2 =Bat >10%

BAT3 =Bat >25%

COZN =Not COZ COZY =COZ

MTNN=No Motion MTNY=In Motion

TTLN=Not OK to Total TTLY=OK to Total

NET*=Net mode GRS*=Gross mode

ACTN = Not Active ACTY = Active

BAT 13.2 Volts

BATTERY NORMAL or BATTERY LOW

TEMP 30C measures internal temp of 9850

Go to Index

Advertising
This manual is related to the following products: