Set points output, Multi-drop output – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 15

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 15

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

Both RS-422 and RS-485 are multi-drop capable.

The 9850 can drive up to 32 receivers on one

twisted pair. Although the 9850 uses standard RS-

485 drivers, the 9850 firmware does not have a full

duplex protocol. Contact MSI for custom solutions

for networking with RS-485.

Comm Port Cable Color Code RS-422/485

Applies to Comm Port 1 Only

Brown TD- (Z)

White TD+ (Y)

Black RD+ (A)

Grey RD- (B)

Blue

Signal Ground

Pink

Ground (to Blue) to configure port for

422/485

Drain Wire Connect to metal shell.
If the 9850 is the final device in a chain, enable

the termination resistor (see Comm Port Menus).

Install a 120Ω resistor at the end of the cable across

RD+ and RD-.

485

Receiver

485

Receiver

485

Receiver

485

Receiver

BROWN

WHITE

BLUE

Shield Drain

485 Termination

Resistor.

120

Ω 1/4W

Final receiver

only.

Terminate Shield

at only one end.

Multi-drop Output

+

+

+

Gnd Pink

Wire to enable

422/485 Mode

+

9850

COMM PORT 1

Pin 1 - TD- (Z)

Pin 2 - TD+ (Y)

Pin 3 - GND

Pin 4 - RD+

Pin 5 - RD-

Pin 6 - Mode

PINK

9850

COMM PORT 1

Pin 1- TD- (Z)

Pin 2 - TD+ (Y)

Pin 3 - GND

Pin 4 - RD+ (A)

Pin 5 - RD- (B)

TD+
TD-

RD-

RD+

GND

CHASSIS

GND

If the 9850 is the

final receiver, enable

the internal termination

(Menu choice).

485 Termination

Resistor. 120

Ω 1/4W

Final receiver only.

Terminate Shield

at only one end.

Ground Reference

Resistor. 100

Ω 1/2W

At all receivers.

Shield

Shield

RS-485/422 Full Duplex Connection

Remote Device

Up to 1000 meters

BRN

WHT

BLUE

BLK

GREY

Pin 6 - Mode

PINK

9850 COMM 1 only

SET POINTS OUTPUT

Set Points Output Cable
The 9850 can directly drive up to 5 external relays which correspond to the CellScale system Set Points 1-5. The

open drain MOSFET output lines are transient and inductive kickback protected so that no snubber network is

needed for coil relays. The drivers are rated for 5-25Vdc relay coils up to 150mA. The Set Points Port provides

a source of 5V, but limit drain from this source to 500mA total maximum.
Set Point outputs 1-4 are always available. Use of Set Point 5 requires that jumper JP6 on the Processor board is

positioned 1-2. This modification requires SMD soldering skills. Normally the line is connected to circuit ground

to allow a power return for use of the 5V supply. Set Point 5 is also shared with the Audible Alarm option regard-

less of the JP6 setting.

1

2

3

4
5

6
7

8

9

Brown (TD-)

(Z)

Black (RD+)

(A)

Blue (GND)

Grey (RD-)

(B)

White (TD+)

(Y)

Jumper 1-6-4

(Optional)

COMM 1 RS-422/485

9-Pin Male ‘D’

Solder Cup View

Pink

(Mode)

120Ω Termination

Resistor

(If necessary)

Go to Index