Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 57

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 57

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

-Wei

g

ht-

CHN ADR

Ch-Name-------------

1-ID-String---------

DateTime-Enter-Num.

Standard Weight – Lines 1-4: Large Current Weight display (-Weight-). Line 5: Chan-

nel Number, and the Network Address. Line 6: the Channel Name (if programmed in the

CellScale). Line 7: ID String 1 (if entered at the CellScale or by the 9850 functions). Line 8:

The Date and Time. When entering numbers, the Time display will be overwritten temporarily.

Total-Wt-ID ........ Shows the Total weight stored in the current ID Code.

#-SamplesI ......... Shows the number of samples totaled and used for statistics for the current ID Code.

IDC ..................... The ID Code number in the form xxI. e.g. 2I is ID Code 2.

IDName-- ........... The ID Code name. The name must be programmed by either the CellScale or the 9850.

xS or xSL ............ The Scan List Index position as stored in the CellScale where x is 1-8. Used on multiple display

presets to show which scan list position is included on the preset display. These can be later

altered to any scan list position 1-32.

SLI ...................... Scan List Index position displayed in the form xSL (positions 1-9) or xxS (positions 10-32).

x’s-Weight .......... Current weight from scan list position x.

x’s-Ch-Name ...... Channel name from scan list position x. Channel names are programmed at the CellScale.

x’s IdNm ............. ID Code Name from scan list position x.

Single Channel Preset Displays
The 9850 utilizes a programmable full dot matrix display capable of multiple font sizes. The smallest font is a

5x7 dot count in a 6x8 cell yielding a maximum character count of 20 characters in 8 lines. The medium font

is a 7x15 in a 8x16 cell which provides up to 4 lines of 16 characters. The large font allows up to two lines of 8

characters. When the weight is displayed in the large font, smaller characters for units, Net/Gross mode, COZ,

and motion allow the large font to contain all necessary weight data. In the following preset display descriptions

the data is located by lines 1-8 relative to the smallest font.

Standard & Products – This display shows ID Code data for Totalizing. Lines 1-4: Large

weight display (-Weight-). Line 5: shows the ID Name and ID Code number. Line 6: the total

weight and the Network Address. Line 7: shows the number of samples in the Total and the

channel number. Line 8: the Date and Time. When entering numbers, the Time display will be

overwritten temporarily.

Net Gross Tare – For applications that need to see the Net weight, Gross weight, and Tare

weight simultaneously. Lines 1-4: Large Net Weight display (-Weight-). Line 5: Gross Weight

and the Channel number. Line 6: The Tare Weight and the network address. Line 7: the Chan-

nel Name (if programmed in the CellScale). Line 8: the Date and Time. When entering num-

bers, the Time display will be overwritten temporarily.

If no Tare value is set the Net weight and Gross weight will equal each other. While in this display the Net/Gross key will have no effect
since both Net and Gross Weight are already shown. However, pressing the Net/Gross key will change the display mode for other devices
connected to the master CellScale.

Standard & Strings – This display shows ID Code Strings for user data entry. Lines 1-4: Large

weight display (-Weight-). Line 5: shows the ID Name and ID Code number. Line 6: the total

weight and the Network Address. Line 7: shows the number of samples in the Total and the

channel number. Line 8: the Date and Time. When entering numbers, the Time display will be

overwritten temporarily.

Maximum Data – This display shows all standard data available for any given scale channel

and associated ID. Line 1: Net Weight and Scan List Index. Line 2: Gross Weight and Chan-

nel Number. Line 3: Tare weight and Network Address. Line 4: the Total Weight and the ID

number (1-32). Line 5: number of totaled samples and the 8 character ID name. Line 6: ID

String 1. Line 7: ID String 2. Line 8: the Date and Time. When entering numbers, the Time

display will be overwritten temporarily.

-Weight------- SLI

Gross-Wt--- CHN

Tare-Wt---- ADR

Total-Wt-ID---- IDC

#-SamplesI IdName--

1-ID-String---------

2-ID-String---------

DateTime-Enter-Num.

-Wei

g

ht-

Gross-Wt--- CHN

Tare-Wt---- ADR

Ch-Name-------------

DateTime-Enter-Num.

-Wei

g

ht-

IDName-- IDC

Total-Wt-ID---- ADR

#-SamplesI CHN

DateTime-Enter-Num.

-Wei

g

ht-

CHN IdName-- ADR

1-ID-String---------

2-ID-String---------

DateTime-Enter-Num.

Go to Index