5.4.1 Topology

5.4.2 Configurations
Bridge 1

DUT#configure terminal

Enter the Configure mode.

DUT(config)#vlan database

Enter the VLAN database mode.

DUT(config-vlan)#vlan 10,20

Create VLAN 10,20

DUT(config-vlan)#exit

Exit VLAN database mode.

DUT(config)#interface eth-0-1

Enter the interface mode.

DUT(config-if)#switchport mode trunk

Set the switching characteristics of this interface trunk
mode.

DUT(config-if)#switchport trunk allowed vlan all

Set this trunk allow all VLANs on this interface.

DUT(config-if)#switchport trunk native vlan 10

Set this trunk port’s PVID to 10.

DUT(config)#interface eth-0-2

Enter the interface mode.

DUT(config-if)#switchport mode access

Set the switching characteristics of this interface access
mode.

DUT(config-if)#switchport access vlan 10

Enable VLAN port access by specifying the VLAN ID 2
on this interface.

DUT(config-if)#end

Exit to exec mode.

DUT#show vlan brief

Display vlan’s configurations.

DUT#show interface switchport

Display interface’s switch configurations.


Bridge 2

DUT#configure terminal

Enter the Configure mode.

DUT(config)#vlan database

Enter the VLAN database mode.

DUT(config-vlan)#vlan 10,20

Create VLAN 10,20

DUT(config-vlan)#exit

Exit VLAN database mode.

DUT(config)#interface eth-0-1

Enter the interface mode.

DUT(config-if)#switchport mode trunk

Set the switching characteristics of this interface trunk
mode.

DUT(config-if)#switchport trunk allowed vlan all

Set this trunk port allow all VLANs on this interface.

DUT(config-if)#switchport trunk native vlan 10

Set this trunk port’s PVID to 10.