Validation

An OAM entity can put its remote entity into loopback mode using a loopback control OAMPDU. In
loopback mode, every frame received is transmitted back on that same port except for OAMPDUs. The
periodic exchange of OAMPDUs must continue during loopback state to maintain the OAM session. Once
we enable remote loopback in Bridge1, it sends out a loopback control OAMPDU with Enable remote
loopback command. When Bridge2 receives it, it changes its parser state to Loopback and MUX state to
discard and then sends out information OAMPDU with updated state information.

Validation Commands

Bridge1

DUT1# show ethernet oam state-machine interface eth-0-9

State Machine Details:

--------------------------------

Local OAM mode: Active

Local OAM enable: Enable

Local link status: OK

Local pdu status: SEND_ANY

Local Satisfied: True

Local Stable: True

Remote Satisfied valid: True

Remote Stable: True

Transmit_state: WAIT_FOR_TX

Local Parser State: Discard

Local Multiplexer State: Forward

Remote Parser State: Loopback

Remote Multiplexer State: Discard

Link Monitoring Event Configuration

We can configure high and low threshold for link-monitoring features. We can also configure an error
disable action if one of the high thresholds is exceeded.

Bridge1


DUT# configure terminal

Enter the Configure mode.

DUT(config)#interface eth-0-9

Specify the interface (eth-0-9)to be
configured and enter the Interface
mode

DUT(config-if)# ethernet oam link-monitor supported

Enable the interface to support link
monitoring. This is the default.

DUT(config-if)# ethernet oam link-monitor on

Start link monitoring.