EXFO FTB-8500 Series for FTB-500 User Manual

Page 102

Advertising
background image

Creating and Starting a Test Case

88

FTB-8500 Series and FTB-8120NGE/8130NGE

Ethernet RFC 2544 Test Case

To create an RFC 2544 test case:
1.
Test configuration:

1a. Select Ethernet 10/100/1000 or

Ethernet 10G as the Interface Type.
Interface Type is not available with
FTB-8510G.

1b. For FTB-8510B: Select the Topology test

type: Single Port or Dual Ports.

1c. Select RFC 2544 as the Application

Type.

1d. Select the desired RFC 2544 sub test(s).

All RFC 2544 sub tests are selected by default.

Throughput: Gives the maximum throughput of the device under
test for which there is no frame loss. Refer to Throughput on
page 302 for more
information.

Back-to-Back: Gives the maximum number of frames that can be
sent at maximum throughput. Refer to Back-to-Back on page 307
for more information.

Frame Loss: Gives the percentage of frames that are lost. Refer to
Frame Loss on page 311 for more information.

Latency: Gives the time required for the sent frame to go through
the device under test. Refer to Latency on page 315 for more
information.

1e. Leave the Dual Test Set check box cleared. For Dual Test Set test

case, refer to Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test
Set Test Cases
on page 78.

1f. Press Next.

Advertising
This manual is related to the following products: