Traffic Filter Configuration

Allows gathering statistics according to the programmed filters. Up to 10
filters having up to four operands each can be defined and enabled.

Note: The Filter Cfg tab is only available when the Advanced Traffic Filtering

software option (SK-ADV-FILTERS) is enabled. Refer to Software Options
on page 378
.

Press TEST, Traffic Analyzer, and Filters Cfg.

Filter Number (Filter No.)

Allows the selection of the filter number (1 to 10).A filter used (enabled)
for data capture will not be configurable and the message Filter in use for
data capture
is displayed; refer to Filter on page 184.

Filter Configuration

The filter configuration section allows to configure the filter criteria for the
selected filter. The configuration is only possible when the Enable check
box is not selected.

(“ and “)“: The open and close parenthesis may be useful to control the
precedence of operands when more than two operands are used. Only
one level of parenthesis is supported. When no parenthesis are used, a
logical AND will have precedence over a logical OR.

Not: When selected, add the logical negation (not equal) operator for the
operand filter defined at its right.