Creating and Starting a Test Case

Ethernet and Fibre Channel Application

105

Ethernet Frame Analyzer Test Case

5. Traffic stream configuration:

5a. Select the traffic stream to be configured, then set its parameters.

Up to 10 streams can be configured with Frame Analyzer test.

5b. For IPv4, select the Automatic IP Address check box to

dynamically obtain an IP address from a DHCP (Dynamic Host
Configuration Protocol) server or set the source and destination IP
addresses, Subnet Mask, and the Default Gateway. Refer to IPv4
Configuration
on page 483 for more infor
mation.

5c. For IPv6, set the destination IP address and if required, press the

IPv6 Config button for additional IPv6 settings. Refer to IPv6
Address Configuration
on page 485 for more infor
mation.

5d. If required, set the network source MAC Address. Select the

Resolve MAC Address check box or set the destination MAC
address. Refer to MAC on page 218 for more information.

5e. Select the Frame Format. Choices are Ethernet II and

802.3 SNAP. Refer to Frame Format on page 218 for more
information.

IPv4