Creating and Starting a Test Case

Ethernet and Fibre Channel Application

95

Ethernet BERT Test Case

2c. For Electrical RJ-45, if required, select

the Ethernet port crossover check box
to inverse the pin-to-pair assignment of
the UTP cable used.

Note: At this point you should have a link up indicated in the Tree view tab. A

green LED indicates a link up while a red LED indicates a link down. For
electrical port, if the link is down, make sure that the Ethernet port
crossover
setting is correct.

2d. Press Next.

3. Optical configuration for Ethernet 10G interface only:

3a. Select the Transceiver Mode Choices

are Local Area Network (LAN) for
regular Ethernet interface
(10.31250Gb/s) and Wide Area Network
(WAN) for Ethernet stream
encapsulated inside a SONET/SDH frame structure (9.95328Gb/s).
Choices availability depend on the unit model and options refer to
Software Options on page 378 for more information.

3b. Select the source Clock Mode (WAN transceiver mode only).

Refer to Clock Synchronization on page 383 for more information.

3c. Press Next.

3d. Enter the J0 Trace and J1 Trace

messages (WAN transceiver mode
only). Refer to WIS TX on page 241 for
more information.

3e. Press Next.