RFC 2544 Tabs

Ethernet and Fibre Channel Application

303

Throughput

Configuration

Test Time (MM:SS): Enter the test time value. Possible values are 1
second to 30 minutes. The default setting is 1 second (00:01).

Accuracy: Enter the accuracy value. The accuracy is not based on the
the configured Maximum Rate but on the Ethernet line rate.

The default setting is 1%. Possible values are:

Select the Accuracy measurement unit. Choices are %, Gbps, and
Mbps. The default setting is %.

Nb. of Acceptable Errors: Select the number of acceptable errors for
the test. Choices are 0 to 10 errors. The default setting is 0 error.

Nb. of Trials to Average: Select the number of times the throughput
test will be generated. Choices are 1 to 50 trials. The default setting is 1
trial.

Nb. of Validations: Select the number of times the result should be
validated. Choices are 1 to 50 times. The default setting is 1 time.

Interface

Accuracy

%

Gbps

MBps

10 Mbps

0.1 to 10

0.00001 to 0.001 0.00125 to 0.125

100 Mbps

0.1 to 10

0.0001 to 0.01

0.0125 to 1.25

1000 Mbps

0.1 to 10

0.001 to 0.1

0.125 to 12.5

10 Gbps

0.1 to 10

0.01 to 1

1.25 to 125