Configuration – EXFO FTB-8500 Series for FTB-500 User Manual

Page 517

Advertising
background image

Pop-Up Windows

Ethernet and Fibre Channel Application

503

Ping

Delay (ms): Available for ping only. Enter the delay between each
attempt (PING). Choices are 100 to 10000 ms. The default setting is
1000 ms.

Data Size (Bytes): Available for ping only. Enter the buffer size that will
be sent to the network device to be detected. Choices are 0 to 1472
bytes
. Default value is 32 bytes.

Time To Live (TTL) for IPv4
Hop Limit (TTL) for IPv6
Enter the maximum number of hops the packet can go through.
Choices are 1 to 255. The default setting is 128.

Flow Label (IPv6 only): Enter the Flow Label number that will be used
to identify a series of related packets from a source to a destination.
Choices are 0 to 1048575. The default setting is 0.

Attempts and Continuous: Enter the number of attempt that will be
performed to reach the network device or press Continuous to
attempt indefinitely. Choices are 1 to 100. The default setting is 4 and
Continuous is disabled.

Type Of Service (TOS) for IPv4
Traffic Class (TOS) for IPv6
Enter the type of service. Choices are 00 to FF. The default setting is 00.

Binary: Enable binary to set the TOS field in binary mode. Otherwise,
the TOS field is in hexadecimal mode. This setting is disabled by
default.

Configuration

Timeout (ms): Enter the maximum time allowed between an ICMP
echo and response at each hop. Choices are 200 ms to 10000 ms. The
default setting is 4000 ms.

Max Hop Count: Enter the maximum network device the packet is
allowed to go through. Choices are 1 to 255. The default setting is 128.

Advertising
This manual is related to the following products: