EXFO FTB-8500 Series for FTB-500 User Manual

Page 347

Advertising
background image

EtherSAM Tabs

Ethernet and Fibre Channel Application

333

Services (Configuration)

Performance Criteria

Max Jitter allows to set the maximum jitter value in millisecond (0.015
to 8000 ms), allowed for the service. The default setting is 2 ms.

Max Round-Trip Latency allows to set the maximum round-trip
latency value in millisecond (0.015 to 8000 ms), allowed for the service.
The default setting is 15 ms. For Dual Test Set, the Max Round-Trip
Latency
is only configurable when the Local to remote direction is
selected. For FTB-8120NGE and FTB-8130NGE in Dual Test Set, only
available when round-trip latency measurement mode is selected.

Max Latency, available on the FTB-8120NGE and FTB-8130NGE
modules in Dual Test Set one-way latency measurement mode, allows
to set the maximum one-way latency value in millisecond (0.015 to 500
ms), allowed for the service. The default setting is 15 ms.

Max Frame Loss allows to set the maximum percentage value (0 to
5%) of Frame Loss allowed for the service. The default setting is 0.1%.

Advertising
This manual is related to the following products: