Tr 101 290 threshold – EXFO FTB-8500 Series for FTB-500 User Manual

Page 299

Advertising
background image

IPTV Tabs

Ethernet and Fibre Channel Application

285

MDI/TR 101 290

TR 101 290 Threshold

TR 101 290 Threshold parameters apply to all streams.

PCR Jitter (ms): Defines the value at which an alarm is declared when
crossed. Choices are from 1 to 1000 ms. The default setting is 10 ms.
The PCR Jitter (ms) check box is selected by default. Clearing the
PCR Jitter (ms) check box will disable alarm reporting for this metric.

PAT Error2 (s): Defines the value at which an alarm is declared when
crossed. Choices are from 0.1 to 5.0s. The default setting is 0.5s. The
PAT Error2 (s) check box is selected by default. Clearing the
PAT Error2 (s) check box will disable alarm reporting for this metric.

PMT Error2 (s): Defines the value at which an alarm is declared when
crossed. Choices are from 0.1 to 5.0s. The default setting is 0.5s. The
PMT Error2 (s) check box is selected by default. Clearing the
PMT Error2 (s) check box will disable alarm reporting for this metric.

PID Error (s): Defines the value at which an alarm is declared when
crossed. Choices are from 0.1 to 5.0 seconds. The default setting is 1.0
s. The PID Erros (s) check box is selected by default. Clearing the
PID Erros (s) check box will disable alarm reporting for this metric.

Advertising