Back-to-back (rfc 2544) – EXFO FTB-8500 Series for FTB-500 User Manual

Page 442

Advertising
background image

Expert Mode Tabs

428

FTB-8500 Series and FTB-8120NGE/8130NGE

Back-to-Back (RFC 2544)

Back-to-Back (RFC 2544)

Press TEST, Expert Mode, and Back-to-Back.

Enable Criteria: Allows to enable Back-to-Back Pass/Fail criteria. This
setting is disabled by default.

Note: Both Enable Criteria and the test itself (see Global Configuration on

page 298) have to be enabled for a specific test to be able to change its
criteria values.

Frame Size: Indicates the frame sizes selected for the test.

TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: For
each frame size, enter the minimum number of frames values at
maximum throughput allowed before declaring a Fail condition.
P1-to-P2/P2-to-P1 is only available with FTB-8510B.

Status: Indicates the real-time pass/fail condition.

Grey LED: Indicates that Expert Mode is disabled or the test did not
run yet.
Green LED: Indicates that the threshold is respected (Pass).
Red LED: Indicates that the threshold is not respected (Fail).

Copy From Measurement button: Copy the performance results from
the test that ran previously and use it as the Pass/Fail criteria. If no test
ran before, default values used will be 0 Frames/Burst.

Advertising
This manual is related to the following products: