RFC 2544 Tabs

314

FTB-8500 Series and FTB-8120NGE/8130NGE

Frame Loss

Frame Loss Results

Frame Size: Indicates the frame sizes used for the test. Up to seven
different frame sizes can be displayed.

Note: The “--” indicates that the result is not available because the test has not

run yet or the measured value is not valid.

TX-to-RX/Local to Remote/Remote to Local: Gives the number of
frames for the corresponding direction. P1-to-P2/P2-to-P1 is only
available with FTB-8510B.

Current Trial: Indicates the current trial number.

Current Step: Indicates the current percentage of the testing rate.

Units: Indicates the throughput result unit which is % Loss.

Displayed Step: Indicates what TX-to-RX/Local to
Remote
/Remote to Local rate result is displayed. This setting is
only available when the test is running or completed.
P1-to-P2/P2-to-P1 is only available with FTB-8510B.

Displayed Results: Select the displayed result mode: Current,
Minimum, Maximum, or Average. The default setting is Current.