Latency measurement – EXFO FTB-8500 Series for FTB-500 User Manual

Page 315

Advertising
background image

RFC 2544 Tabs

Ethernet and Fibre Channel Application

301

Global Configuration

Latency Measurement

Note: Available with FTB-8120NGE and FTB-8130NGE modules only in Dual Test

Set mode.

Latency Measurement Mode: Allows to select either Round-Trip (default)
or One-Way as the latency measurement mode.

To perform one-way latency measurement, the module must be
synchronized with an external 1PPS signal (refer to Clock on page 31).
One-Way latency is only possible when both the local and remote 1PPS
signal clocks are valid. The following alarms are available with One-Way
latency measurement mode.

LOPPS-L and LOPPS-R (Loss Of Pulse Per Second - Local/Remote) is
declared when either no pulse is received or when no pulse is received
within 1 second ± 6.6 μs after the previous pulse. LOPPS-R is only
monitored once the DTS connection is established.

Advertising
This manual is related to the following products: