EXFO FTB-8500 Series for FTB-500 User Manual

Page 124

Advertising
background image

Creating and Starting a Test Case

110

FTB-8500 Series and FTB-8120NGE/8130NGE

Ethernet Smart Loopback Test Case

3. Framing configuration:

3a. Set the

Auto-Negotiation,
Speed, Duplex, and
Flow Control
parameters. Refer to
Interface Setup
(Ethernet)
on page 140

for more information.

3b. Select the Frame

Format. Choices are
Ethernet II and
802.3 SNAP. Refer to
Network on page 148 for
more information.

3c. Set the IP Version(IPv4 or IPv6) IP Version is only available when

the IPv6 software option (SK-IPV6) is enabled.

3d. Set the IP Address, Enable DHCP, Subnet Mask, and Default

Gateway parameters. Refer to Source IP Configuration on
page 150 for more
information.

3e. Press Finish to complete the test setup. The Alarm summary tab

is automatically displayed.

4. Press the Start button to start the test.

5. For additional results, refer to Traffic Analyzer Tabs on page 159.