Functions

Current Period SPL, L

eq

, L

tm3

, L

tm5

, L

max

, and three L

n

values

(for example L

10

, L

50

and L

90

).

Memory Profile Mode

One to four minutes L

eq

based parameter per period to provide pro-

files for up to approx. 720 periods (approx. 499 periods on B
version).

Environmental. Mode

Periods from 5 to 999 minutes may be selected and for each,
results of L

eq

, L

tm3

, L

tm5

, L

max

, L

10

, L

50

& L

90

are calculated.

Maximum number of periods approx. 90. (approx. 60 periods
on B version)

Event Mode

Up to approx. 180 events stored on A version, defined on a
threshold basis (20dB scale deflection) with time of oc-
curence, duration, SEL and L

max

values. (approx. 119 periods

on B version)

Analyser

Approx. 35 octave or approx. 15 third octave (or combination)
analyses along with all-pass and sweep start time.

Attenuator Range

10dB steps 10 - 90dB. 60dB auto ranging on bar graph.

Frequency Range

5Hz - 25kHz Linear or A- weighted for A and C versions.
5Hz - 20kHz Linear or A-weighted for B and D versions.