Then click on the button Initial Position for the very last tag of the matrix bottom right,
the plotter moves to the beginning of the last tag, the upper left corner.

The peak of the pen or hairline cross needs to match with the corner point.
In order to find the exact corner point you can move the plotter with the four cursor
buttons to the exact position.

After making the amendment, you need to click the Apply button in order to apply the
data; the original database remains unchanged. Close the window and the plotter
goes back to its initial position.

You can return to the original settings at any time by clicking on the Reset button in
the window.

Note:
Any change of the scale factor can only be done this way for tags stored in the general
database, user designed tags can be changed by using the designer function.