Shape, Slope, Type – Proel PRONET v.2.1 User Manual

Page 39: Bypass, Default button

Advertising
background image

39

Shape

Shape controls the aspect of equalization filter, depending from the filter type selected.
For Parametric, Ban Pass and Notch filter types the parameter assume the meaning of “width of the bell

shape” of the filter, usually defined as “Q” or “Bandwidth”:
Q (Quality factor) is the ratio of the center frequency (Frequency parameter) of the filter and the bandwidth

measured at the -3 dB points.
Bw (Bandwidth) in octave fractions with steps of 1/20-octave (measured at -3dB points).
In PRONET “Settings” you can select if you use the “Q” or “Bw” representation of the filter's shape.
For 1st-order All Pass filters the shape parameter set the phase (degree) at the reference frequency.
For 2nd-order All Pass filters and Resonant LP and HP filters the shape parameter can set only Q (quality

factor) as in analog filters.
This parameter is not available for shelving filters.
Shape can be edited in the numeric edit box, can be scrolled by the spin buttons or by the up/down arrow

keys of your keyboard, or can be edited with the mouse by a combination of left-click and wheel on the

frequency response window.

Slope

Slope parameter controls the slope of variable shelving filters: for these filters the slope can vary from

6dB/oct to 12 dB/oct in 0.5dB steps.
This parameter is not available for other filter types.
Slope can be edited in the numeric edit box, can be scrolled by the spin buttons or by the up/down arrow

keys of your keyboard, or can be edited with the mouse by a combination of left-click and wheel on the

frequency response window.

Type

This drop-down menu select the type of filter used, it is available only when the filter cell is bypassed. Note

that changing the filter type restores a default setup condition for many parameters of the filter cell.
Filter types available are: Parametric, Notch, High and Low Shelving 6dB/oct, High and Low Shelving

12dB/oct, High and Low variable slope Shelving, Resonant High Pass and Low Pass, Band Pass, 1st order All

Pass, 2nd order All Pass.

Bypass

Checking this option bypasses the equalizer cell.

Default button

Pressing this button restores a default condition for the filter’s parameters, according with the selected type.

Advertising