Threshold, Time, Above/below – Proel PRONET v.2.1 User Manual

Page 42: Side/norm

Advertising
background image

42

Threshold

Sets the working range of the dynamic gain control. In the working range region (see Above/Below

parameter)the gain of the dynamic filter is controlled by the input signal level. The amount of gain or

reduction is displayed by the dyn. gain meter. The threshold level is referred to the maximum dynamic for the

input signal of the dynamic eq. cell, so Thresh=+21dB means “threshold at the maximum level of input

signal”.

Time

Determines how quickly the dynamic equalizer reacts to signals that match the threshold conditions or how

quick the DEQ restores the normal state when signals don’t match these conditions.
Label

Attack Time (ms)

Release Time (ms)

Fast 1

1

10

Fast 2

4

40

Medium 1

8

80

Medium 2

20

200

Medium 3

40

400

Slow 1

80

800

Slow 2

100

1000

Fig.57 Time definitions for DEQ cells.

Above/Below

Selects if the dynamic equalizer works above the threshold or below the condition.

Side/Norm

Selects if the detection block “analyze” the whole signal (normal mode) or a filtered signal (side chain mode).

The filter applied for the side chain depends from the type of filter selected for the signal as in the Fig.58:
Signal filter type

Side chain filter

Low Shelving at freq. f

0

Low pass, cut freq. f

0

Peaking centered at f

0

pass band centered at f

0

High Shelving

High pass, cut freq. f

0

Fig.58 Side chain filters.

On

Enables or disables the single dynamic eq. cell.

Advertising