17. Press the Automatic soft key.

If instructed to increase or decrease transport
speed, do as instructed until the message “Feed
1 Product now” appears.




Tab Sensor setup. Press EXIT when done.
V=1.95, Trip=1.50, Backing=0.10, Tab=1.99
Status: Advanced
Backing V Tab V Automatic EXIT

18. Feed 1 Product (one piece of media).

The tabber will place 2 or 3 tabs on the media
and stop.





Feed 1 Product now
Current liner type is: Clear
Opaque Clear EXIT

Tab Sensor setup. Press EXIT when done.
V=0.09, Trip=0.96, Backing=1.86, Tab=0.07
Status: Advanced
Backing V Tab V Automatic EXIT

19. Verity the correct t voltages:

In this case (running translucent tabs with a
black line between each tab), the Backing
voltage (gap between tabs) should read higher
than the Tab voltage (tab and backing). If the
reading is opposite then you need to verify that
you have selected the correct liner type. In this
example, the liner type “clear” was selected.

20. Press EXIT twice to return to the “Startup Screen”.

21. To begin running the job, make sure the tabber is in the operate mode before pressing the RUN

button.