126

RC2500 Antenna Controller

Appendix L

Replacing the Electrospace 93C-23

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA

www.researchconcepts.com

RC2500 Pin #
& (resource)

Description

83MC4 Pin #

(0.4V = direction CCW)

2

Drive Ground (return path for AZ, EL, & POL drive
command and limit status lines)

DRIVE GND TB3-1,2

3 (PA0)

Azimuth Enable, pull-down drive, 700mA max sink. (0.4V
= AZ move)

AZ EN TB3-3

4 (PA4)

Elevation Enable, pull-down drive, 700mA max sink.
(0.4V = EL move)

EL EN TB3-7

5

Drive Ground (return path for AZ, EL, & POL drive
command and limit status lines)

DRIVE GND TB3-1,2

6 (PA3)

Azimuth Brake, solid state drive, 700mA max sink. (0.4V
= AZ Brake release)

AZ BRK TB3-6

7 (PA7)

Elevation Brake, solid state drive, 700mA max sink. (0.4V
= EL Brake release)

EL BRK TB3-10

8

Drive Ground (return path for AZ, EL, & POL drive
command and limit status lines)

DRIVE GND TB3-1,2

9 (PA6)

EL Slew, solid state drive, 700mA max sink. (PC1 0.4V =
EL Fast Slew)

EL SLEW TB3-??

10 (PB0)

Azimuth CCW Limit Status input, 24 VDC low
current.(same as J6-16) not used here.

No connect

11

nc

12

nc

13

nc

14 (P2.4)

Azimuth Interlock Status input, 24 VDC low current. (0V =
AZ fault)

AZ INTLK TB3-17

15 (HSI.1)

Elevation Interlock Status input, 24 VDC low current. (0V
= EL fault)

EL INTLK TB3-20

16 (PB7)

Drive Ground (Emergency Stop status return)

DRIVE GND TB3-1,2

17 (PB0,
HSI.1, P2.4)

Drive Ground (Interlock Status and Az CCW Lim return;
same as J6-4)

DRIVE GND TB3-1,2

18 (PB0,
HSI.1, P2.4)

Drive Ground (Interlock Status and Az CCW Lim return;
same as J6-4)

DRIVE GND TB3-1,2

19 (PB7)

System Interlock Status Input, 24 VDC low current.
(ESTOP input, 0V = Emergency STOP)

SYSTEM INTLK TB3-16

20

Nc

21 (PA2)

AZ Slew, solid state drive, 700mA max sink. (0.4V = AZ
Fast Slew)

AZ SLEW TB3-??

22 (PA5)

Elevation Direction, pull-down drive, 700mA max sink.
(0.4V = move DOWN)

EL UP/DWN TB3-8

23 (PC2)

Polarization Enable, pull-down drive, 700mA max sink.
(0.4V = POL move)

POL EN TB3-??

24 (PB6)

System Interlock status input, 24 VDC low current. (0V =
ESTOP or Interlock open)

SYSTEM INTLK
TB3-16

25 (PB6)

ACU / Local Status input, low current return path (0V =
Local Pedestal controls active.)

ACU/LOCAL STATUS
TB3-13

In addition to a Maintenance status indication, the Voltage on pin 24 is used to power the electronic

components that reside on the A.I.U.-side of the opto-isolation barrier. When no System Interlock Input is

present, this pin must still be powered by between +15 and +28V (and its return line connected to “-“) in

order for the RC2500 drive system to function.