Research Concepts RC2500 User Manual

Page 150

Advertising
background image

RC2500 Antenna Controller

Appendix O

Replacing the Andrew APC100/ APC 300 143

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas 66218-9680 • USA

www.researchconcepts.com

a) Record the value of the display offset associated with the axis.

b) Reset the display offset associated with the axis by entering 0.0 at the appropriate CONFIG

mode prompt.

c) Reset the lower limit associated with the axis (azimuth CCW, elevation down, or polarization

CCW) by entering 0.0 at the appropriate CONFIG mode prompt.

d) If resetting the azimuth limits set the Azimuth CW Limit to 359.99. If resetting the elevation or

polarization limits, set the Elevation Up Limit or Polarization CW Limit to –0.01.

e) Reinitialize the offset associated with the axis whose limits are being reset to the value

recorded in step a above.

Rc25_lmkds_add.doc completed 4.2.00 by SMM