RC2500 Antenna Controller

Appendix E

RC2500 Comm Protocol

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA

www.researchconcepts.com

byte 5

checksum

The reply to this command will be the same as the reply to the status poll query command except the

command code will be 34h. Note that the NAK reply will be sent back to the host if there are no satellites

available in the RC2500’s memory or if the Pol Control Equipment Code CONFIG mode item is set to 0

(No Pol Control). Note that if the Pol Control Equipment Code is set to 2 (2 Port Feed) there is only one

polarization position associated with the satellite and receipt of this command with either the ‘H’ or ‘V’

argument will result in a move to the single polarization position associated with the satellite. If TRACK

mode is active and a peaking or search operation is in progress this command will not be executed until

after the peaking or search operation terminates. If this occurs the normal acknowledgment will be sent

to the host.

Miscellaneous Command

This command performs miscellaneous functions. Here is the format of the command.

byte 0

STX

byte 1

A

where A is the RC2500 address

byte 2

36h

the miscellaneous command code

byte 3

'X'

the sub-command code

byte 4

'Y'

the sub-command parameter

byte 5

ETX

byte 6

checksum

The sub-command code 'X' can have the following values ...

'X' = 'R'

This specifies the azimuth or elevation drive reset command.
This accomplishes the same function as the RESET mode of the
RC2500: it allows the user to reset the azimuth, elevation, or
polarization alarms. When the sub-command code is 'R', the
sub-command parameter 'Y' must be either 'A', 'E', or 'P' (for
azimuth, elevation, or polarization respectively) to specify which
axis will be reset. If the 'P' command is specified, the command
will be accepted only if the Pol Control Equipment Code
CONFIG mode item is set to 1 (ONE PORT) or 2 (TWO PORT).

'X' = 'T'

This sub-command is used to reset track mode errors (sub-
command parameter 'Y' = R). When the TRACK mode ERROR
sub-mode is active this command will cause the ERROR sub-
mode to terminate. The controller will react as if TRACK mode
was activated via AUTO mode. Note that if a system error is
active (an error message flashing on the bottom row of the
display) the condition which generated the system error must be
rectified or the controller will probably return to the TRACK mode
ERROR sub-mode. This sub-command can also be used to
switch frequency bands when a dual band satellite is being
tracked. A sub-command parameter of 'C' will specify C band
and a sub-command parameter of 'K' will specify K band. The
reply to this command will be a NAK if TRACK mode is not
active, the satellite being tracked was not specified as a dual
band satellite (when the track was initiated via SETUP mode), or
if track polarization movement is not allowed (see byte 32 of the
device status poll command). If polarization movements are not
allowed the controller is either peaking the antenna or
performing a search. Changing the band during a peaking
operation or search can cause the antenna to not accurately
peak the antenna.

The reply to this command will be the same as the reply to the status poll query except the command

code will be '36h'.