Research Concepts RC2500 User Manual

Page 70

Advertising
background image

RC2500 Antenna Controller

Chapter 7

Error Codes

63

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA

www.researchconcepts.com

818 divided by 50 equals 16 with a remainder of 18. For this case the Peakup Holdoff Interval will be (18

* 10) or 180 seconds.

The Peakup Holdoff Interval should be longer than the worst case time that it takes to perform a peaking

operation. The worst case peakup time will correspond to the portion of the satellite's apparent motion

when the satellite is passing through the earth's equatorial plane.

Advertising