Lightning protection – H3C Technologies H3C SR6600-X User Manual

Page 15

Advertising
background image

5

CAUTION:

Check the resistance of the ESD-preventive wrist strap for safety. The resistance reading should be in the
range of 1 to 10 megohm (Mohm) between human body and the ground.

The SR6602-X does not provide any ESD-preventive wrist strap. Prepare it yourself.

Figure 2 Use an ESD-preventive wrist strap

(1) ESD-preventive wrist strap

(2) Lock

(3) Alligator clip

EMI

All electromagnetic interference (EMI) sources, from outside or inside of the router and application system,

adversely affect the router in a conduction pattern of capacitance coupling, inductance coupling,

electromagnetic wave radiation, or common impedance (including grounding system) coupling. To
prevent EMI, perform the following tasks:

Take measures against interference from the power grid.

Do not use the router together with the grounding equipment or light-prevention equipment of
power equipment, and keep the router far away from them.

Keep the router far away from high-power radio launchers, radars, and equipment with high
frequency or high current.

NOTE:

Use electromagnetic shielding when necessary.

Lightning protection

To protect the router from lightning better, do as follows:

Make sure the chassis is well grounded.

Make sure the grounding terminal of the AC power receptacle is well grounded.

1

2

3

Advertising