Cooling system failure – H3C Technologies H3C SR6600-X User Manual

Page 80

Advertising
background image

70

The router deletes its main and backup next-startup configuration files and restores the

factory-default configuration.

The current mode is no password recovery. The configuration files will be

deleted, and the system will start up with factory defaults, Are you sure to

continue?[Y/N]Y

Setting...Done.

3.

When the EXTEND-BOOTWARE menu appears again, enter 0 to reboot the router.
The router starts up with the factory-default configuration.

4.

Configure a new console login password (see "

Configure a new console login password.

") or

new user privilege level passwords (see "

Configure new passwords for user privilege levels.

").

5.

To make the settings take effect after a reboot, save the running configuration to the next-startup
configuration file.

[H3C] save

Cooling system failure

When the environmental temperature of a module reaches or exceeds the high temperature threshold,

the fans rotate at full speed, and the following information appears on the configuration terminal:

%Dec 7 11:49:16:436 2011 H3C DRVMSG/3/TEMP_WARNING:

Environment temperature is greater than warning upper limit in slot 0, index is 1.

#Dec 7 11:49:20:444 2011 H3C DEVM/1/BOARD TEMPERATURE UPPER:

Trap 1.3.6.1.4.1.25506.8.35.12.1.16<hh3cBoardTemperatureHigher>: chassisIndex is 0,

slotIndex 0.0

%Dec 7 11:49:20:444 2011 H3C DEVM/4/BOARD_TEMP_TOOHIGH: Board temperature is too high

on Chassis 0 Slot 0, type is SR6602-X2.

After the router runs for a period of time, the environmental temperature of the router will drop below the
high temperature threshold, and the following information appears on the configuration terminal:

%Dec 7 11:50:11:436 2011 H3C DRVMSG/3/TEMP_NOWARNING:

Environment temperature recovered from TEMP_WARNING in Slot 0, index is 1.

%Dec 7 11:50:11:436 2011 H3C DRVMSG/3/TEMP_SYSNOWARNING:

System temperature recovered from TEMP_WARNING.

#Dec 7 11:50:13:244 2011 H3C DEVM/1/BOARD TEMPERATURE NORMAL:

Trap 1.3.6.1.4.1.25506.8.35.12.1.17<hh3cBoardTemperatureFormHigherToNormal>:

chassisIndex is 0, slotIndex 0.0

%Dec 7 11:50:13:244 2011 H3C DEVM/5/BOARD_TEMP_NORMAL: Board temperature changes to normal

on Chassis 0 Slot 0, type is SR6602-X2.

When the environmental or CPU temperature of a module exceeds the critical temperature threshold, the
ALM LED of the router is red.

%Dec 7 11:17:01:436 2011 H3C DRVMSG/3/TEMP_ALARM:

CPU temperature is greater than alarm upper limit in slot 0, index is 0.

To view the high temperature threshold and critical temperature threshold of each module, use the
display environment command.