Him/mim failures, Configuration system problems, No terminal display – H3C Technologies H3C SR6600-X User Manual

Page 74

Advertising
background image

64

#Dec 6 17:13:58:847 2011 H3C DEVM/1/FAN STATE CHANGES TO FAILURE:

Trap 1.3.6.1.4.1.25506.8.35.12.1.6<hh3cfanfailure>: fan ID is 1

%Dec 6 17:13:58:847 2011 H3C DEVM/2/FAN_FAILED: Fan 1 failed.

The output shows that fan 1 is faulty.
To solve the problem, check whether any foreign object has entered the fan tray.
If the cause cannot be located in the steps above and the problem persists, contact your local sales

agent.

HIM/MIM failures

When a HIM/MIM is plugged while the router is running, the following information may appear on the
configuration terminal:

%Dec 30 09:54:10:264 2011 66mcp DRVICOUT/1/DrvIcOutStr:

Card in Slot 4 Sublot 2 can not be recognized !

The output indicates that the HIM/MIM is faulty or the router cannot recognize the HIM/MIM.
To troubleshoot the HIM/MIM failure:

1.

Check whether the HIM/MIM is firmly seated.

2.

Check whether the HIM is correctly plugged into an FIP-20 module. An FIP-10 module does not
support HIMs.

3.

Check whether the interface module connector pins of the FIP module are bent.

4.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

Configuration system problems

If the configuration environment setup is correct, the configuration terminal displays boot information
when the router is powered on. If the setup is incorrect, the configuration terminal displays nothing or

garbled text.

No terminal display

If the configuration terminal displays nothing when the router is powered on, To troubleshoot the failure:

1.

Check the following items.

{

The power supply system works properly.

{

The console cable is properly connected.

2.

If no problem is found, check the following reasons that may apply:

{

The console cable is connected to an incorrect serial port (the serial port in use is not the one
set on the terminal).

{

The properties of the terminal are incorrect. You must configure the console terminal as follows:
set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, Flow control to None,

and Terminal Emulation to VT100.

{

The console cable fails.