Fip module failure, Power module failures – H3C Technologies H3C SR6600-X User Manual

Page 72

Advertising
background image

62

CPU temperature is greater than alarm upper limit in slot 0, index is 0.

To solve the problem, check the output (such as the system temperature, insufficient available power, and

PCB voltage alarms) on the serial terminal and the software management tool.
If the cause cannot be located in the steps above and the problem persists, record the above information,

and contact your local sales agent.

Table 20 Router status LED description

LED Status Remarks

PWR1 (red/green)

Off

The power module is not in position.

Steady green

The power module is supplying power properly.

Steady red

No power is input or the power module is faulty
when PWR2 is operating properly.

PWR2 (red/green)

Off

The power module is not in position.

Steady green

The power module is supplying power properly.

Steady red

No power is input or the power module is faulty
when PWR1 is operating properly.

FAN (red/green)

Off

No power is input or the fan tray is not is position.

Steady green

The fan tray is operating properly.

Steady red

The fan tray is faulty.

ALM (red)

Steady on

No alarm exists.

Off

The router is faulty. You need to view the system
logs immediately.

RUN (green)

Off

No power is input or the router is faulty.

Flashes at 1 Hz

The router is operating properly.

Flashes at 8 Hz

The router is loading software or has not started.

FIP module failure

If the RUN LED of the FIP module is off, it indicates that the FIP module is powered off or faulty.
To troubleshoot the FIP module failure:

1.

Check whether the router is powered on.

2.

If the router is powered on, check whether the FIP module is plugged in a right slot.

3.

If the FIP module is plugged in a right slot, it indicates that the FIP module is faulty. Contact your
local sales agent.

Power module failures

If the router cannot be powered on and the power LED on the front panel is off, it indicates that the power

module is faulty.
To troubleshoot the power module failure:

1.

Check whether the power switch is turned on.

Advertising