27

Figure 30 Connect an E1 75-ohm cable

If you want to extend the cable, connect each BNC connector of the E1 75-ohm cable to one end
of a coaxial connector, and connect the remote device to the other end of the coaxial connector

through an E1 75-ohm adapter cable.

Figure 31 Connect an E1 75-ohm cable

If the impedance of the E1 interface on the remote device is 120 ohms, you must use an impedance
converter to adapt the impedance.

Figure 32 Connecting an impedance converter

Connecting a T1 cable

1.

Connect the D68 connector of the 8-port T1 cable to the D68 interface on the interface module and

fasten the bolts to fix the cable.

……

E1 / E1-F
(75ohm)

TX

RX

Device

(120ohm E1 Port)

E1 75-ohm cable

Straight-through cable

Impedance converter