Troubleshooting, Router failures, Power status leds are off – H3C Technologies H3C SR6600-X User Manual

Page 71: Run led is off, Run led fast flashes, Alm led is steady on or flashes

Advertising
background image

61

Troubleshooting

NOTE:

The barcode stuck on the router chassis contains production and servicing information. Before you return
a faulty router for serving, provide the barcode information of the router to your local sales agent.

Router failures

Power status LEDs are off

When the PWR1 and PWR2 LEDs are off, the power module of the router is faulty. For more information

about the PWR1 and PWR2 LEDs, see “

Appendix B LEDs

.”

To troubleshoot the problem:

1.

Check whether a power module is plugged in a right slot.

2.

Check whether the power module is powered on normally. A green PWR LED indicates that the
router is powered on properly.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

RUN LED is off

When the RUN LED of the router is off, it indicates that the router is faulty. For more information about the

RUN LED, see “

Appendix B LEDs

.”

To troubleshoot the problem, contact your local sales agent.

RUN LED fast flashes

Five minutes after the router is powered on, if the RUN LED still fast flashes at 8 Hz, it indicates that the

system software image fails to start or the router is faulty.
To troubleshoot the problem:

1.

Check whether the terminal display is correct.

2.

Check whether the system software image file properties are correct in the BootWare menu.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

ALM LED is steady on or flashes

If the ALM LED is steady on or flashes, it indicates that the router is faulty. The ALM LED may be on in the

following cases.

When the system is over-temperature. In this case, the system displays the following output:

%Dec 7 11:17:01:436 2011 H3C DRVMSG/3/TEMP_ALARM:

Advertising