Replacing the ttr supply hub and adjusting plate – Genicom 3600 User Manual

Page 106

Advertising
background image

3600 Printer Maintenance Manual

5-20

Replacing the TTR Supply Hub and Adjusting Plate

To replace the TTR supply hub, the TTR supply hub adjusting plate, or both
parts, you will need some or all of the following parts and tools:

TTR supply hub, Intermec Part No. 061562-004

TTR supply hub adjusting plate, Intermec Part No. 062603-001

Retaining snap rings, Intermec Part No. 501410

Ribbon supply hub alignment tool, Intermec Part No. T43149

ESD grounding strap

Snap ring pliers

#1 and #2 Phillips screwdriver

To remove the TTR supply hub and TTR supply hub adjusting plate

1. Switch off the printer power and remove the power cord.

2. Remove the media cover, the electronics cover, and the front bezel cover

(refer to “Replacing the Bezel PCB” earlier in this chapter).

3. Raise the printhead. Remove media and ribbon if loaded.

4. Remove the two retaining snap rings and thin washer from the electronics

side of the TTR supply hub shaft as shown on the next page. Retain the
washer. Discard the old snap rings.

5. Pull the TTR supply hub away from the printer and remove the TTR

supply clutch/encoder assembly. Retain the TTR supply clutch/encoder
assembly (this assembly is not a spare part), the nylon washer, and the
thick steel washer.

6. You can replace the TTR supply hub and TTR supply hub adjusting plate

now.

Advertising