Replacing the label taken sensor – Genicom 3600 User Manual

Page 98

Advertising
background image

3600 Printer Maintenance Manual

5-12

Replacing the Label Taken Sensor

To replace the label taken sensor, you will need the following parts and tools:

Label taken sensor cable assembly, Intermec Part No. 059496-002

ESD grounding strap

#1 and #2 Phillips screwdriver

To replace the label taken sensor

1. Switch off the printer power and remove the power cord.

2. Remove the media cover, the electronics cover, and the front bezel cover

(refer to “Replacing the Bezel PCB” earlier in this chapter).

3. Raise the printhead. Remove media and ribbon if loaded.

4. Disconnect the label taken sensor cable from the main PCB, remove the

cable from the two plastic clips, and push it through the cutout in the main
deck plate. Slide the sensor housing away from the main deck plate.

3600M.050

Label taken
sensor

Main
deck
plate

5. Install the new sensor, routing the cable through the cutout in the main

deck plate and plugging it into the main PCB. Place the cable in the plastic
clips with the black sleeve positioned as close as possible to the sensor end.

6. Reattach the front bezel cover. Ensure that the media access door operates

properly (snaps firmly shut) after the front bezel cover is installed.

7. Reload media (and ribbon if used) and lower the printhead.

8. Install the electronics cover, the media cover, and the power cord, and

check the printer for proper operation.