Adjusting the Print Bias for Print Quality

Adjust the bias with a straight-slot screwdriver if the printhead is not making
even contact with the media. Using different width media, especially narrow
media, can result in uneven contact or a spot where there is no media between
the printhead and the platen roller. Extra wear and damage can occur if narrow
media is used for extended periods with incorrect bias.

To adjust the bias adjust screw

1. Remove the media cover and locate the bias adjust screw.

Power

Intermec

Intermec

3600

Alert

Feed/Pause

Intermec

Intermec

3600

Empty/Pause

3600M.030

Printhead bias
adjust screw

2. Turn the bias adjust screw counterclockwise to compensate for light print

on the right side of the label; turn the bias adjust screw clockwise to
compensate for light print on the left side.

3600M.031

*N AR

RO

WL

E*

*N

AR

RO

WL

E*

If printing is light on
the right side of label,
turn the bias adjust screw
counterclockwise.

If printing is light on
the left side of label,
turn the bias adjust screw
clockwise.

3. Install the media cover.