Replacing the ac plug/input filter – Genicom 3600 User Manual

Page 117

Advertising
background image

Remove and Replace Procedures

5-31

5

Replacing the AC Plug/Input Filter

To replace the AC plug and input filter assembly, you will need the following
parts and tools:

3600 line AC plug and filter assembly, Intermec Part No. 060246-001

ESD grounding strap

#1 and #2 Phillips screwdriver

Needlenose pliers

To replace the AC plug and input filter

1. Switch off the printer power and remove the power cord, the media cover,

and the electronics cover.

2. Disconnect the three push-on connectors attached to the back of the AC

plug/input filter assembly.

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

3600M.062

O

I

(2 places)

AC power
plug & filter

Push-on
connectors

3. Remove the two screws securing the AC plug/input filter assembly to the

main deck plate and remove the assembly.

4. Install the new AC power plug and input filter assembly and secure it with

the two screws removed in Step 3.

5. Reconnect the three push-on connectors removed in Step 2.

6. Install the electronics cover, the media cover, and the power cord, and

check the printer for proper operation.

Advertising