Error & Status Messages

39

4

A3:Error

There is too much data for the
I/O buffer to handle.

Check if the interface cable
is inserted into the printer
and the computer securely.

Check if the interface cable
is damaged or broken.

Increase the size of the I/O
buffer.

⇒ P.79 “Using the

Operation Panel”

A6:Error

There is not enough printer
memory to print one or more of
the pages in the print job.

See P.114 “Low Memory”.

AB:Error

The printer is unable to process
the data you are trying to print.

Install optional memory
unit to increase the amount
of printer memory.

Reduce the amount of data
being sent to the printer.

B0:Error

An error has occurred in the
optional memory unit.

Turn the printer off and on.
Then, try to print again.

Turn off the printer. Re-
move and reinstall the
memory unit and turn on
the printer. Then, try to
print again.

Turn off the printer. Re-
move the memory unit and
turn on the printer. Then,
try to print again.

Note

❒ In this case, you might

not be able print com-
plex print jobs.

B1:Error

An error has occurred in the
standard parallel interface.

Contact your sales or ser-
vice representative.

B3:Error

The printer setting is wrong.

Reset the printer using
"Menu Reset" of the "Main-
tenance" menu.

⇒ P.79 “Us-

ing the Operation Panel”

B5:Error

An error has occurred in the
RICOH-SCRIPT2 module.

Contact your sales or ser-
vice representative.

Message

Description

Comments