Table 2.2

SCSI Parity Control

EPC

AESP

Description

0

0

Does not check for parity errors. Parity is generated when sending
SCSI data. Asserts odd parity when sending SCSI data.

0

1

Does not check for parity errors. Parity is generated when sending
SCSI data. Asserts even parity when sending SCSI data.

1

0

Checks for odd parity on SCSI data received. Parity is generated
when sending SCSI data. Asserts odd parity when sending SCSI
data.

1

1

Checks for odd parity on SCSI data received. Parity is generated
when sending SCSI data. Asserts even parity when sending SCSI
data.

1. Key:

EPC = Enable Parity Checking (bit 3,

SCSI Control Zero (SCNTL0)

).

ASEP = Assert SCSI Even Parity (bit 2,

SCSI Control One (SCNTL1)

).

Table 2.3

SCSI Parity Errors and Interrupts

DPH

PAR

Description

0

0

Halts when a parity error occurs in the target or initiator mode and
does not generate an interrupt.

0

1

Halts when a parity error occurs in the target mode and generates
an interrupt in target or initiator mode.

1

0

Does not halt in target mode when a parity error occurs until the
end of the transfer. An interrupt is not generated.

1

1

Does not halt in target mode when a parity error occurs until the
end of the transfer. An interrupt is generated.

Key:
DHP = Disable Halt on SATN/ or Parity Error (bit 5,

SCSI Control One (SCNTL1)

.

PAR = Parity Error (bit 0,

SCSI Interrupt Enable Zero (SIEN0)

.

This table only applies when the Enable Parity Checking bit is set.