Table 5. DSA Preboot messages (continued)

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a Trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Message
number

Component Test

State

Description

Action

217-901-xxx SAS/SATA

Hard Drive

Disk Drive
Test

Failed

1. Reseat all hard disk drive backplane

connections at both ends.

2. Reseat all drives.

3. Run the test again.

4. Make sure that the firmware is at the latest

level.

5. Run the test again.

6. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

405-901-xxx BroadCom

Ethernet
Device

Test
Control
Registers

Failed

1. Make sure that the component firmware is

at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.

2. Run the test again.

3. Replace the component that is causing the

error. If the error is caused by an adapter,
replace the adapter. Check the PCI Information
and Network Settings information in the DSA
event log to determine the physical location of
the failing component.

4. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

96

Hardware Maintenance Manual