• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

Fault in slot System board
on system %1.(%1 =
CIM_ComputerSystem.ElementName)

Error

1. Check the extender-card

LEDs.

2. Reseat the affected adapters

and extender card.

3. Update the server and adapter

firmware (UEFI and IMM).

Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.

4. Remove both adapters.

5. Replace the PCIe adapter.

6. Replace the extender card.

7. (Trained service technician

only) Replace the system
board.

Redundancy Bckup Mem Status has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Check the system-event

log for DIMM failure events
(uncorrectable or PFA) and
correct the failures.

2. Re-enable mirroring in the

Setup utility.

IMM Network Initialization Complete.

Info

An IMM network has
completed initialization.

No action; information only.

Certificate Authority %1 has detected
a %2 Certificate Error.(%1 =
IBM_CertificateAuthority.CADistinguishedName;
%2 =
CIM_PublicKeyCertificate.ElementName)

Error

A problem has occurred with
the SSL Server, SSL Client,
or SSL Trusted CA certificate
that has been imported
into the IMM. The imported
certificate must contain a
public key that corresponds
to the key pair that was
previously generated by
the Generate a New Key
and Certificate Signing
Request
link.

1. Make sure that the certificate

that you are importing is
correct.

2. Try importing the certificate

again.

Ethernet Data Rate modified from
%1 to %2 by user %3.(%1 =
CIM_EthernetPort.Speed; %2 =
CIM_EthernetPort.Speed; %3 = user
ID)

Info

A user has modified the
Ethernet port data rate.

No action; information only.

40

Hardware Maintenance Manual

Advertising
This manual is related to the following products: