Lenovo 6532 User Manual

Page 33

Advertising
background image

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

3808000

IMM communication failure

1. Remove power from the server for 30 seconds, and

then reconnect the server to power and restart it.

2. Update the IMM firmware to the latest level (see

“Updating the firmware” on page 211).

3. Make sure that the virtual media key is seated and

not damaged.

4. (Trained service technician only) Replace the

system board.

3808002

Error updating system configuration to IMM

1. Remove power from the server, and then reconnect

the server to power and restart it.

2. Run the Setup utility and select Save Settings.

3. Update the IMM firmware to the latest level (see

“Updating the firmware” on page 211).

3808003

Error retrieving system configuration from
IMM

1. Remove power from the server, and then reconnect

the server to power and restart it.

2. Run the Setup utility and select Save Settings.

3. Update the IMM firmware to the latest level (see

“Updating the firmware” on page 211).

3808004

IMM system event log full

• When using out-of-band, use the IMM Web

interface or IPMItool to clear the logs from the
operating system.

• When using the local console:

1. Run the Setup utility.

2. Select System Event Log.

3. Select Clear System Event Log.

4. Restart the server.

3818001

Core Root of Trust Measurement (CRTM)
update failed

1. Run the Setup utility, select Load Default Settings,

and save the settings.

2. (Trained service technician only) Replace the

system board.

3818002

Core Root of Trust Measurement (CRTM)
update aborted

1. Run the Setup utility, select Load Default Settings,

and save the settings.

2. (Trained service technician only) Replace the

system board.

3818003

Core Root of Trust Measurement (CRTM)
flash lock failed

1. Run the Setup utility, select Load Default Settings,

and save the settings.

2. (Trained service technician only) Replace the

system board.