• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

0010002

Microprocessor not supported.

1. (Trained service technician only) Reseat the

microprocessor and restart the server.

2. (Trained service technician only) Remove the

microprocessor and install a new microprocessor.
Restart the server. If the error is corrected, the old
microprocessor is bad and must be replaced.

3. Replace the following components one at a time, in

the order shown, restarting the server each time.

a. (Trained service technician only) Microprocessor

b. (Trained service technician only) System board

0011000

Invalid microprocessor type.

1. Update the server firmware to the latest level (see

“Updating the firmware” on page 211).

2. (Trained service technician only) Remove and

replace the affected microprocessor (error LED
is lit) with a supported type (see “Installing the
microprocessor” on page 141).

0011004

Microprocessor failed BIST.

1. Update the server firmware to the latest level (see

“Updating the firmware” on page 211).

2. (Trained service technician only) Reseat the

microprocessor.

3. Replace the following components one at a time, in

the order shown, restarting the server each time:

a. (Trained service technician only) Microprocessor

b. (Trained service technician only) System board

001100A

Microcode updated failed.

1. Update the server firmware to the latest level (see

“Updating the firmware” on page 211).

2. (Trained service technician only) Replace the

microprocessor.

0050001

DIMM disabled.

1. If the server fails the POST memory test, reseat the

DIMMs.

2. Remove and replace any DIMM for which the

associated error LED is lit (see “Removing a
memory module” on page 125
and “Installing a
memory module” on page 125
).

3. Run the Setup utility to enable all the DIMMs.

4. Run the DSA Preboot memory test (see “Running

the diagnostic programs” on page 65).

20

Hardware Maintenance Manual