• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

0058007

DIMM population is unsupported.

1. Reseat the DIMMs, and then restart the server.

2. Remove the lowest-numbered DIMM pair of those

that are identified and replace it with an identical
pair of known good DIMMs, then restart the server.

3. Return the removed DIMMs, one pair at a time, to

their original connectors, restarting the server after
each pair, until a pair fails. Replace the DIMMs in
the failed pair with identical known good DIMMs,
restarting the server after each DIMM is installed.
Replace the failed DIMM. Repeat this step until you
have tested all removed DIMMs.

4. (Trained service technician only) Replace the

system board.

0058008

DIMM failed memory test.

1. Reseat the DIMMs, and then restart the server.

2. Replace the following components one at a time, in

the order shown, then restart the server after each:

a. DIMM

b. (Trained service technician only) System board

00580A4

Memory population changed.

Information only. Memory has been added, moved,
or changed.

0068002

CMOS battery cleared.

1. Reseat the battery.

2. Clear the CMOS memory (see System board

jumpers).

3. Replace the following components one at a time,

in the following order, restarting the server after
each one:

a. Battery

b. (Trained service technician only) System board

2011001

PCI-X PERR

1. Check the riser-card LEDs.

2. Reseat all affected adapters and riser cards.

3. Update the PCI adapter firmware.

4. Remove the adapter from the riser card.

5. Replace the following components one at a time, in

the order shown, restarting the server each time:

a. Riser card

b. (Trained service technician only) System board