System-event log – Lenovo 6532 User Manual

Page 34

Advertising
background image

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

3818004

Core Root of Trust Measurement (CRTM)
system error

1. Run the Setup utility, select Load Default Settings,

and save the settings.

2. (Trained service technician only) Replace the

system board.

3818005

Current Bank Core Root of Trust Measurement
(CRTM) capsule signature invalid

1. Run the Setup utility, select Load Default Settings,

and save the settings.

2. (Trained service technician only) Replace the

system board.

3818006

Opposite bank CRTM capsule signature
invalid

1. Switch the server firmware bank to the backup

bank (see “Starting the backup server firmware”
on page 212).

2. Run the Setup utility, select Load Default Settings,

and save the settings.

3. Switch the bank back to the primary bank.

4. (Trained service technician only) Replace the

system board.

3818007

CRTM update capsule signature invalid

1. Run the Setup utility, select Load Default Settings,

and save the settings.

2. (Trained service technician only) Replace the

system board.

3828004

AEM power capping disabled

1. Check the settings and the event logs.

2. Make sure that the Active Energy Manager feature

is enabled in the Setup utility. Click System
Settings
® Power ® Active Energy Manager ®
Capping Enabled .

3. Update the server firmware to the latest level (see

“Updating the firmware” on page 211).

4. Update the IMM firmware to the latest level (see

“Updating the firmware” on page 211).

System-event log

The system-event log contains messages of three types:

26

Hardware Maintenance Manual

Advertising
This manual is related to the following products: