• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a Trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Message
number

Component Test

State

Description

Action

201-802-xxx Memory

Memory
Test

Aborted Test

canceled:
the end
address in
the E820
function is
less than 16
MB.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that all DIMMs are enabled in the

Setup utility.

4. Make sure that the DSA code is at the latest

level. For the latest level of DSA code, go to
http://www.lenovo.com/support.

5. Run the test again.

6. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

201-803-xxx Memory

Memory
Test

Aborted Test

canceled:
could not
enable the
processor
cache.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the server firmware is at

the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.

4. Run the test again.

5. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

201-804-xxx Memory

Memory
Test

Aborted Test

canceled:
the memory
controller
buffer
request
failed.

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the server firmware is at

the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.

4. Run the test again.

5. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..