Lenovo 6532 User Manual

Page 93

Advertising
background image

Table 5. DSA Preboot messages (continued)

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which

components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a Trained service technician.

• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,

hints, tips, and new device drivers or to submit a request for information.

Message
number

Component Test

State

Description

Action

166-906-xxx IMM

IMM I2C
Test

Failed

The IMM
indicates
a failure in
the memory
configuration
bus (Bus 5).

1. Turn off the system and disconnect it from

the power source. You must disconnect the
system from ac power to reset the IMM.

2. After 45 seconds, reconnect the system to the

power source and turn on the system.

3. Run the test again.

4. Make sure that the DSA code is at the latest

level. For the latest level of DSA code, go to
http://www.lenovo.com/support.

5. Make sure that the IMM firmware is at the latest

level. The installed firmware level is shown in
the DSA event log in the Firmware/VPD section
for this component. For more information, see
“Updating the firmware” on page 211.

6. Run the test again.

7. Turn off the system and disconnect it from the

power source.

8. Trained service technician only) Replace the

system board.

9. Reconnect the system to the power source and

turn on the system.

10. Run the test again.

11. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..

201-801-xxx Memory

Memory
Test

Aborted Test

canceled:
the system
UEFI
programmed
the memory
controller
with an
invalid CBAR
address

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the server firmware is at

the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211
.

4. Run the test again.

5. If the failure remains, go to the Lenovo Web site

for more troubleshooting information at
http://www.lenovo.com/support..