Lenovo 6532 User Manual

Page 168

Advertising
background image

6. Touch the static-protective package that contains the new ServeRAID-BR10il SAS/SATA controller to

any unpainted surface on the outside of the server; then, grasp the controller by the top edge or upper
corners of the controller and remove it from the package.

7. Align the ServeRAID controller

1

so that the keys align correctly with the connector

2

on the system

board.

8. Insert the ServeRAID controller into the connector on the system board until it is firmly seated. The

retention bracket secures the ServeRAID controller in place when the controller is firmly seated into
the connector on the system board.

Attention: Incomplete insertion might cause damage to the server or the controller.

9. Route the signal cables from the drive backplane through the fan cage hole (between fans 1 and 2)

as shown in the following illustration.

160

Hardware Maintenance Manual

Advertising